ABSTRACT Based on above-described requirement,we dispread the design of RTU by meeting of remote measurement, remote signaling, remote tuning and remote controlling that is namely “four-remote”. In lectotype of RTU system, we have met all the requirement of shandong electric fence. Particularly, as a major plant our station has achieved AGC function finely. In the future following our station developping , RTU remains enough redundancy. Although the capacity of power unit is very large, but the investment and working expenses is much lower than the same kind power plant.This embodied economics and practicability. We may know advance and science of RTU for liaocheng power station by this article. It has suitable reference sense for scale-large generating station plant.
KEY WORD: RTU DESIGN LECTOTYPE
摘要:本文圍繞滿足遙測、遙信、遙調(diào)、遙控即“四遙”功能展開了我廠遠(yuǎn)動系統(tǒng)的設(shè)計。在遠(yuǎn)動裝置的選型上,不僅滿足了山東電網(wǎng)對聊城廠的全部要求,特別是很好的解決了我廠作為主力電廠應(yīng)具備的AGC功能。而且為我廠的將來發(fā)展留下了足夠的冗余度。盡管機組容量較大,但投資及運行費用比同類發(fā)電廠卻低的多,體現(xiàn)了經(jīng)濟性與實用性。通過本文了解我廠遠(yuǎn)動系統(tǒng)的先進性、科學(xué)性,對大型發(fā)電廠遠(yuǎn)動有一定借鑒意義。
關(guān)鍵詞: 遠(yuǎn)動裝置 設(shè)計 選型
1 背景
山東中華發(fā)電公司聊城發(fā)電廠為大型中外合資企業(yè),在山東聊城市西郊,位于山東、山西、河北三省的交界處,是山東電網(wǎng)的一個主要電源點,是電網(wǎng)西部一個強有力的電壓支撐點。山東聊城發(fā)電廠遠(yuǎn)期規(guī)劃為4*600MW 機組, 一期工程現(xiàn)安裝2*600MW 機組,電廠2*600MW 機組直接以發(fā)電機-變壓器-線路組單元制接線接至新建的220KV 北郊開關(guān)站。在調(diào)度上由山東電力調(diào)度中心直接調(diào)度管理。在未來的發(fā)展上,在實現(xiàn)山東電網(wǎng)與華北網(wǎng)乃至全國聯(lián)網(wǎng)時,鑒于聊城特殊的地理位置,它將起到非常關(guān)鍵的作用。因此,實現(xiàn)它的自動化調(diào)度就逾顯得重要。對調(diào)度自動化的基礎(chǔ)設(shè)施——遠(yuǎn)動終端裝置的設(shè)計就是必需的了。
由于遠(yuǎn)動終端是調(diào)度自動化的基礎(chǔ)設(shè)施,遠(yuǎn)動工程屬系統(tǒng)工程。因此,我們在方案設(shè)計時,要充分考慮到聊城發(fā)電廠在山東電力系統(tǒng)中的作用、地位及各方面的情況,如所需RTU 的數(shù)量、每個RTU 的容量,即現(xiàn)場可采集的點數(shù)及其要求的刷新時間、RTU 的安裝地點、所能利用的通信設(shè)施及通信設(shè)備采用的通信技術(shù)等。還有,如何利用RTU 實現(xiàn)山東電力調(diào)度自動化為聊城發(fā)電廠所提出的調(diào)峰調(diào)頻任務(wù)。另外,我們還要考慮到投資的經(jīng)濟性及運行維護的方便性。通過本次設(shè)計,我們需要解決聊城廠遠(yuǎn)動裝置的選型,與遠(yuǎn)動裝置相關(guān)的變送器選型,與硬件相配套的軟件系統(tǒng)及與其它設(shè)備的通訊問題。使得遠(yuǎn)動終端能夠很好的為山東電力自動化調(diào)度傳送準(zhǔn)確的現(xiàn)場數(shù)據(jù),實現(xiàn)“四遙”功能。方便檢修維護人員和管理人員對發(fā)電現(xiàn)場參數(shù)的了解。
2 遠(yuǎn)動系統(tǒng)的的用途及構(gòu)成
遠(yuǎn)動系統(tǒng)的用途是把發(fā)電廠或變電站的數(shù)據(jù)隨時傳送給各級調(diào)度所,供調(diào)度人員及其他有關(guān)人員使用;蛘邚恼{(diào)度所把控制或調(diào)節(jié)信號傳送到有關(guān)現(xiàn)場。用專業(yè)術(shù)語來說就是“遙測”(遠(yuǎn)方測量),“遙信”(遠(yuǎn)方信號),“遙控”(遠(yuǎn)方控制),“遙調(diào)”(遠(yuǎn)方調(diào)節(jié)),簡稱“四遙”。遠(yuǎn)動系統(tǒng)是調(diào)度自動化的基礎(chǔ)設(shè)施。從現(xiàn)場(發(fā)電廠或變電站)往調(diào)度所應(yīng)該傳送的數(shù)據(jù):
發(fā)電機組的出力(MW,MVAR)
發(fā)電機組的發(fā)電電度(MWH,MVARH)
母線電壓
發(fā)電機的最大限值(上限值、下限值)
發(fā)電機的控制限值
有關(guān)機組的性能參數(shù)諸如:燃料消耗率,水位、
油位等信號
線路潮流(MW、MVAR)
主變壓器負(fù)荷(MW、MVAR)
主變壓器分接頭位置
主變壓器的調(diào)壓方式(自動,手動)
開關(guān)和隔離開關(guān)的狀態(tài)(合,分)
繼電保護信號
事故總信號
線路的電度
事件順序(幾個開關(guān)相繼跳閘的時間)
從調(diào)度所往現(xiàn)場發(fā)送的命令:
遙控命令,例如:拉/合開關(guān),投/切水電機組,改變變壓器分接頭位置等遙調(diào)命令,例如改變發(fā)電機組的出力以上所傳遠(yuǎn)動數(shù)據(jù)首先供給調(diào)度員使用,以便全面掌握電網(wǎng)運行情況,及時采取措施進行調(diào)度。其次,供其它部門使用,例如:繼電保護人員及時了解繼電保護裝置是否動作正確,或者為什么誤動,各個開關(guān)掉閘的先后順序。檢修部門可以根據(jù)開關(guān)的操作次數(shù)來編排檢修計劃,生產(chǎn)統(tǒng)計部門感興趣的是有關(guān)機組的發(fā)電電度,廠用電指標(biāo),燃料利用情況。主管部門也可以在辦公室里觀看彩色屏幕上的遠(yuǎn)動數(shù)據(jù)了解電力系統(tǒng)的運行情況。所以,遠(yuǎn)動系統(tǒng)一般由一個調(diào)度端(也叫主站)和若干遠(yuǎn)動裝置(也叫終端RTU)經(jīng)過通道組成一體。調(diào)度自動化系統(tǒng)一般由以下三部分組成:
現(xiàn)場端的有關(guān)遠(yuǎn)動設(shè)備;通道;調(diào)度端的在線運行的計算機系統(tǒng)。目前,把上述三個部分構(gòu)成了不可分割的整體叫做能量管理系統(tǒng)(EMS),其功能包括:監(jiān)控和數(shù)據(jù)收集系統(tǒng)(SCADA);自動發(fā)電控制和經(jīng)濟調(diào)度控制(AGC/EDC);安全分析和對策;調(diào)度員培訓(xùn)模擬(DTS)。
3 聊城廠遠(yuǎn)動信息的傳送方式的選擇
遠(yuǎn)動信息的傳送方式有兩種:循環(huán)傳送方式(CDT)和查詢方式(POLLING).循環(huán)傳送方式的特點是RTU 主動的以循環(huán)方式向調(diào)度端發(fā)送信息。我們運行的國產(chǎn)RTU 大多數(shù)都采用這種方式。一次循環(huán)叫做一幀。遠(yuǎn)動裝置就一幀接著一幀的不停的發(fā)送信息。查詢方式的特點是:主動端是調(diào)度端而RTU 是被動端。調(diào)度端主動向RTU 發(fā)命令要求RTU 發(fā)送信息,RTU 只有正確收到調(diào)度端發(fā)來的查詢命令后才能往調(diào)度端發(fā)送信息。所以這種方式也叫對話式。對于RTU 來講“有問必答,不問不答”決不許主動向調(diào)度端發(fā)送信息。接入RTU 的遙信和遙測點要劃分不同的類別。類別是依照不同的更新速率而劃分的。對于調(diào)度員經(jīng)常監(jiān)視的量就應(yīng)該頻繁的查詢。反之,對于次要的量就應(yīng)隔比較長的時間查詢一次。由于把RTU 的所有點進行分類,規(guī)定好各自的更新速率,因此調(diào)度端就能根據(jù)需要分類查詢。顯而易見,查詢方式的優(yōu)點是減少了通道負(fù)載,減少了調(diào)度端計算機的開銷,因此,對聊城廠與中調(diào)之間信息傳送的方式采用SC1801 問答式傳輸規(guī)約,因聊城廠屬于山東省調(diào)直接調(diào)度,因此,只保留與聊城電業(yè)局地調(diào)留有CDT 循環(huán)式規(guī)約并保留相應(yīng)的通訊接口,目前,對聊城電業(yè)局不傳送遠(yuǎn)動數(shù)據(jù)。
4 遠(yuǎn)動裝置的選型及安裝
4.1 RTU 硬件設(shè)備的選型
在現(xiàn)場的有關(guān)遠(yuǎn)動設(shè)備中最重要的是終端RTU.它是電力系統(tǒng)和調(diào)度自動化系統(tǒng)之間的接口設(shè)備。RTU 的功能是對現(xiàn)場的電氣量和狀態(tài)信息進行采集,A/D 轉(zhuǎn)換、編碼進行并/串轉(zhuǎn)換后發(fā)向調(diào)度端,同時調(diào)度端發(fā)來的命令進行解碼串/并轉(zhuǎn)換后對現(xiàn)場電…………